Filter und Tools: Produkte gegen Schadstoffe, Geruchsstoffe und biogene Korrosion

Filters & Tools

Simple.Flexible.Ready.

 

We provide you with the best products for immediate 

and effective control of pollutants, malodour 

and corrosion:

Filters & Tools

Products to eliminate pollutants, odorous substances and biogenic corrosion

The fouling process of wastewater often starts as early as in the sewer or the force main. Causes for this include low flow rate, long residence time, high temperatures and low pH value. This results in the formation of hydrogen sulphide (H2S) – a toxic gas that causes unpleasant odours. On top of that, even low H2S concentrations can lead to concrete degradation. Sewage structures are thus destroyed, which results in high investment costs.

We have the products you need for immediate and effective pollutant, malodour, and corrosion control:

Your benefits at a glance

PROFIT FROM

  • Low costs of purchase
  • Low need for filtering material
  • Flexible adjustment to process modifications
  • Low maintenance effort
  • Guaranteed compliance with pollutant emission levels
  • Odour control
  • Corrosion protection
  • High degree of profitability and operational reliability

AREAS OF APPLICATION

  • Wastewater facilities
  • Standard and special size manholes (DN 600, DN 800, etc.)
  • Pumping station covers
  • Ventilation domes (e. g., Huber system)
  • Exhaust air ducts from pumping stations, grease traps, chemical and biological sewage plants
  • Exhaust air outlets from storage and expansion tanks, chemical tanks
  • For low to extremely high H2S loads
  • For organic and inorganic malodorous substances and pollutants

Biofilter or hybrid filter ... always a solution that fits your needs

All UGN® filters are available as biofilter or hybrid filter customized to your specific requirements. The filter type is determined by the filtering material. We are happy to assist you with our advice.

ABOUT BIOFILTERS

Filled with filtering material

Our biofilters are particularly suitable for exhaust air with low and continuous loads of malodorous and pollutants as well as for manholes that are checked on a regular basis.

The malodorous and polluted exhaust air is led through the biofilter and flows through the biologically active UgnCleanPellets® Basis filtering material.

In this process the filtering material absorbs the pollutants contained in the exhaust air, which are then broken down by microorganisms. The clean, non-smelling and pollutant-free air is then released into the atmosphere.

ABOUT HYBRID FILTERS

    Filled with filtering material

Our hybrid filters are particularly suitable for exhaust air containing high, variable, or discontinuous loads of malodorous substances and pollutants with high peak loads. They are capable of removing pollutants in concentrations of up to several 1,000 ppm.

The malodorous and polluted exhaust air is led through the hybrid filter and flows through the biologically active UgnCleanPellets® S 1.0 filtering material (or, UgnCleanPellets® S 3.5 at very high concentrations of hydrogen sulphide). In this filtering material the chemical loading and biological degradation processes run in parallel. The chemical adsorber contained in the UgnCleanPellets® S buffers the pollutants and malodorous substances which are broken down by microorganisms afterwards. The non-smelling and clean air is released into the atmosphere.

This continuous regeneration means that the filtering material maintains its takeup capacity for many years.

Abluftreinigungsanlagen: UGN-BEGA-System zur gezielten Belüftung und Entlüftung mit integrierter Abluftreinigung, Verfahrenskonzept 4. Filtermaterial

UGN® Top filter

Application

  • Pollutant and odour filter for installation on top of ducts
  • Made for treatment of humid and loaded exhaust air from vent chimneys, flues, well covers, tanks, grease interceptors, surge, collection, and process tanks, impoundments, sanitation vents, reservoirs, etc.

Product description

  • Available for all standard pipe dimensions
  • Up to 15 m³/h purifying capacity
  • Made of corrosion resistant, UV-proof plastic material
  • Two-piece filter consisting of cartridge and cartridge body
  • Hood option available for rain protection

UGN-Aufsatzfilter zweiteilige Filterkonstruktion aus Kunststoff, Schadstoff- und Geruchsfilter zum Aufsetzen auf Belüftungskamine, Entlüftungskamine, Brunnenabdeckungen, Tanks
Einsatzbeispiel mit Haube: UGN-Aufsatzfilter, Schadstoff- und Geruchsfilter zum Aufsetzen auf Belüftungskamine, Entlüftungskamine, Brunnenabdeckungen, Tanks
Einsatzbeispiel: UGN-Aufsatzfilter, Schadstoff- und Geruchsfilter zum Aufsetzen auf Belüftungskamine, Entlüftungskamine, Brunnenabdeckungen, Tanks

UGN® Manhole biofilter

Application

  • Pollutant and odour filter for installation underneath manhole covers
  • Prevents sewer damage due to corrosion
  • Effective treatment of exhaust air from sewer and grease interceptor vents

Product description

  • Suitable for all manhole covers and for BEGU and VIATOP systems
  • Up to 15 m³/h purifying capacity
  • Natural shaft ventilation is fully maintained
  • Made of corrosion resistant, UV-proof plastic material
  • Comprising two parts, a base plate and a removable filter cartridge – which can replaced with an infiltration water barrier when needed
    UGN-Kanalschachtfilter mit Grundplatte und Filterpatrone, für den Einbau im Deckel eines Kanalschachtes, um lästigen Geruch zu vermeiden und korrosiven Schäden im Kanalsystem vorzubeugen
    Einsatzbeispiel: UGN-Kanalschachtfilter, eingebaut im Deckel eines Kanalschachtes, um lästigen Geruch zu vermeiden und korrosiven Schäden im Kanalsystem vorzubeugen
    Einsatzbeispiel: UGN-Kanalschachtfilter, eingebaut im Deckel eines Kanalschachtes, um lästigen Geruch zu vermeiden und korrosiven Schäden im Kanalsystem vorzubeugen

    UGN® Pipe filter

    Application

    • Pollutant and odour filter for installation on top of, or integration in, vent and flue pipes
    • Designed for effective treatment of exhaust air from sewage ventilation (toilet facilities, small sewage plants) and grease interceptor ventilation

    Product description

    • Available for all standard pipe dimensions
    • The filter can be inserted at any point in the existing pipe sleeve or by means of a slip-on sleeve.
    • Filter made of corrosion resistant, UV-proof plastic material
    • Sealing is ensured by pipe seals
    UGN-Rohrfilter aus Kunststoffrohr, Schadstoff- und Geruchsfilter zum Auf- und Zwischenstecken in Be- und Entlüftungsrohre
    Einsatzbeispiel: UGN-Rohrfilter, Schadstoff- und Geruchsfilter zum Auf- und Zwischenstecken in Be- und Entlüftungsrohre von Sanitäranlagen
    Einsatzbeispiel: UGN-Rohrfilter, Schadstoff- und Geruchsfilter zum Auf- und Zwischenstecken in Be- und Entlüftungsrohre von Kleinkläranlagen

    UGN® Pipe filter cartridge

    Application

    • Pollutant and odour filter for integration in vent and flue pipes
    • Can be used when insertable filters (such as UGN® pipe filters) cannot be reused as is the case with, e. g., stainless steel piping
    • Effective treatment of exhaust air from pumping chambers, vent domes, well covers, etc.

    Product description

    • Available for all standard pipe dimensions
    • Can be integrated in the pipe at any place and is not visible from outside
    • Cartridge made of corrosion resistant, UV-proof plastic material
    UGN-Rohrfilterpatrone aus Kunststoffrohr, Schadstoff- und Geruchsfilter zum Einsetzen in Be- und Entlüftungsrohre von Pumpenschächten, Entlüftungsdomen, Brunnenabdeckungen
    Einsatzbeispiel: UGN-Rohrfilterpatrone, Schadstoff- und Geruchsfilter zum Einsetzen in Be- und Entlüftungsrohre von Pumpenschächten, Entlüftungsdomen, Brunnenabdeckungen
    Einsatzbeispiel: UGN-Rohrfilterpatrone, Schadstoff- und Geruchsfilter zum Einsetzen in Be- und Entlüftungsrohre von Pumpenschächten, Entlüftungsdomen, Brunnenabdeckungen

    UGN® Universal filter

    Application

    • Universal pollutant and odour filter for installation in 30 × 50 cm or 50 × 50 cm manhole covers
    • Effective treatment of exhaust air from street and backyard drains flown through by rain and waste water, and covers of sewage plants, expansion, and storage tanks

    Product description

    • Oval (manhole cover 30 × 50 cm) or round (manhole cover 50 × 50 cm) types
    • Natural shaft ventilation is fully maintained
    • Made of corrosion resistant, UV-proof plastic material
    • One-piece system – filter cartridge fixed to base plate
    • Sealing is ensured by exact fitting and PUR seal, if necessary
    Einsatzbeispiel: UGN-Universalfilter, runde Ausführung, universeller Filtereinsatz für Straßen- und Hofabläufe, Tanks, Abdeckungen von Kläranlagen
    UGN-Universalfilter, runde und ovale  Ausführung, universeller Filtereinsatz für Straßen- und Hofabläufe, Tanks, Abdeckungen von Kläranlagen
    Einsatzbeispiel: UGN-Universalfilter, ovale Ausführung, universeller Filtereinsatz für Straßen- und Hofabläufe, Tanks, Abdeckungen von Kläranlagen

    UGN® Air trap

    Application

    • Air trap for installation in 30 × 50 cm or 50 × 50 cm manhole covers
    • Immediate removal of outgassing from street and courtyard drains flown through by rain and waste water

    Product description

    • Oval (manhole cover 30 × 50 cm) or round (manhole cover 50 × 50 cm) types
    • Featuring integrated flap and dirt trap – surface water drain remains unobstructed
    • Made of corrosion resistant, UV-proof plastic material
    Einsatzbeispiel: Geruchsverschluss zur Beseitigung von Ausgasungen in abwasser- bzw. regenwasserdurchflossenen Straßen- und Hofabläufen
    Einsatzbeispiel: Geruchsverschluss zur Beseitigung von Ausgasungen in abwasser- bzw. regenwasserdurchflossenen Straßen- und Hofabläufen
    Einsatzbeispiel: Geruchsverschluss zur Beseitigung von Ausgasungen in abwasser- bzw. regenwasserdurchflossenen Straßen- und Hofabläufen

    UGN® Sewer infiltration water barrier

    Application

    • For installation underneath manhole covers
    • Prevents ingress of excess surface water resulting from, e. g., flooding, meltwater, and heavy rain or snowfall
    • Suitable for permanent use

    Product description

    • Suitable for all manhole covers and for BEGU and VIATOP systems
    • Can be generally used up to 1 m water column
    • Manhole ventilation is maintained
    • Made of corrosion resistant, UV-proof plastic material
    • Comprising two parts, a base plate and a removable cartridge, containing the infiltration water barrier

    If needed, this cartridge system can be replaced by a biofilter or hybrid filter cartridge  (for odour and pollutant elimination).

    UGN-Fremdwasserverschluss komplett mit Grundplatte und herausnehmbarem Fremdwasserverschluss als Patrone zum Einbau in den Deckel eines Kanalschachtes, um starken Oberflächenwassereintritt zu verhindern
    Einsatzbeispiel: UGN-Fremdwasserverschluss zum Einbau in den Deckel eines Kanalschachtes, um starken Oberflächenwassereintritt zu verhindern.
    Einsatzbeispiel: UGN-Fremdwasserverschluss zum Einbau in den Deckel eines Kanalschachtes, um starken Oberflächenwassereintritt zu verhindern.

    UGN® Odour and emission barrier

    Application

    • Flexible gas blocker for installation in vertical and horizontal pipes
    • For reliable control of noxious emissions and odour nuisance
    • Prevents gas from escaping while allowing free flow of water

    Product description

    • Available for all standard pipe dimensions
    • Elastic, transparent PVC membrane/barrier
    • Elastic, self-sealing barrier with flexible segments for vertical pipes
    • Freely swinging membrane for horizontal pipes
    Geruchs- und Emissionsblocker, freischwingende, aufschwimmende Gasaustrittssperre gegen Geruchsbelästigung für den Einbau in waagerecht oder senkrecht geführte Rohrleitungen
    Einsatzbeispiel: Geruchs- und Emissionsblocker, freischwingende, aufschwimmende Gasaustrittssperre gegen Geruchsbelästigung für den Einbau in waagerecht oder senkrecht geführte Rohrleitungen
    Einsatzbeispiel: Geruchs- und Emissionsblocker, freischwingende, aufschwimmende Gasaustrittssperre gegen Geruchsbelästigung für den Einbau in waagerecht oder senkrecht geführte Rohrleitungen

    UGN® Flexible segment valve

    Application
    Freely swinging, floating gas blocker for odour control to be installed in horizontal pipelines with a nominal diameter > 300 mm, and for shafts

    Product description

    • prevents gas from escaping while allowing free flow of water
    • Elastic, transparent PVC membrane
    • Stainless steel fasteners
    • Removable
    Einsatzbeispiel: Konvektionsschleier, freischwingende, aufschwimmende Gasaustrittssperre gegen Geruchsbelästigung für den Einbau in waagerecht geführte Rohrleitungen
    Einsatzbeispiel: Konvektionsschleier, freischwingende, aufschwimmende Gasaustrittssperre gegen Geruchsbelästigung für den Einbau in waagerecht geführte Rohrleitungen
    Einsatzbeispiel: Konvektionsschleier, freischwingende, aufschwimmende Gasaustrittssperre gegen Geruchsbelästigung für den Einbau in waagerecht geführte Rohrleitungen
    +49 (0) 365 - 830 58 98
    info@ugn-umwelttechnik.de
    go to downloads